General Specifications
- Manufacturer Integrated Power Designs
- Form Factor Enclosed
- Power 300 Watts
- Input 85-264 VAC
- Outputs Sinlge, Dual, Triple, or Quadruple
- Warranty 2 Year Warranty
Models
Model #
Output
- CE-300-5001 5V, 24V, 12V, -5V, -12V
- CE-300-5002 5V, 12V, -12V, -5V, 24V
- CE-300-5003 5V, 12V, 24V, -15V, 15V
- CE-300-5004 5V, 24V, 24V, -12V, 12V
- CE-300-5005 24V, 12V, 5V, -15V, 15V
- CE-300-5006 24V, 24V, 5V, -15V, 15V
- CE-300-5012 5V, 28V, 12V, -5V, -12V
- CE-300-5013 5V, 3.3V, 24V, -5V, 12V
- CE-300-4001 5V, 12V, -5V, -12V
- CE-300-4002 5V, 24V, 12V, -12V
- CE-300-4003 5V, 24V, 15V, -15V
- CE-300-4004 24V, 12V, 5V, -12V
- CE-300-4005 5V, -5.2V, 12V, -12V
- CE-300-4006 24V, 12V, -12V, 5V
- CE-300-4007 24V, 15V, 5V, -15V
- CE-300-4009 24V, 12V, 5V, -12V
- CE-300-4011 5V, 3.3V, 12V, -12V
- CE-300-3001 5V, 12V, 12V
- CE-300-3002 5V, 12V, 24V
- CE-300-3003 5V, 15V, -15V
- CE-300-3004 12V, 12V, 5V
- CE-300-3006 5V, 3.3V,12V
- CE-300-2001 5V, 24V
- CE-300-2002 12V, -12V
- CE-300-2003 15V, -15V
- CE-300-2004 24V, -24V
- CE-300-1001 5V
- CE-300-1002 12V
- CE-300-1003 15V
- CE-300-1004 24V
Mechanical
- Dimensions 4.9x 8.5x 1.95 inches
- Operating Temperature 0°C + 50°C
- Cooling Method Internal Fan
-
Agency Approvals
General: Protection Class- I, Over voltage catagory- II, Pollution Degree- 2
UL: UL 60950-1, CAN/CSA-C22.2 No. 60950-1-03
TUV: EN 60950-1:2001
CE: Low voltage directive
IEC: CB Report per IEC 60950-1(2001)
Output
- Voltage Accuracy Outputs 1-5: ±0.5%
- Line Regulation 0.50%
- Load Regulation 1%
- Minimum Load 10%
-
Protections
Over Voltage: Output 1: 120%-150%, Shuts down all outputs. Cycle input to restart
Over Current: 110% min, outputs 2,3,4,5
Over power: 340 W min, outputs cycle on/off auto recovery