General Specifications
- Manufacturer Integrated Power Designs
- Form Factor U Bracket
- Power 225 Watts
- Input 85-264 VAC
- Outputs Single, Dual, Triple or Quadruple
- Warranty 2 Year Warranty
Models
Model #
Output
- CE-225-4001 3.3V, 5V, 12V, -12V
- CE-225-4002 5V, 3.3V, 12V, -12V
- CE-225-4003 5V, 3.3V, 15V, -15V
- CE-225-4004 5V, -5.2V, 12V, -12V
- CE-225-4005 5V, -5.2V, 15V, -15V
- CE-225-4006 5V, 12V, 12V, -12V
- CE-225-4007 5V, 12V, 15V, -15V
- CE-225-4008 5V, 12V, 9V, -9V
- CE-225-4101 5V, 24V, 12V, -12V
- CE-225-4102 5V, 24V, 15V, -15V
- CE-225-4104 24V, 24V, 12V, 5V
- CE-225-3001 5V, 12V, -12V
- CE-225-3002 5V, 15V,-15V
- CE-225-2001 12V, -12V-
- CE-225-2002 15V, -15V
- CE-225-2003 5V, 12V
- CE-225-2004 5.2V, -9V
- CE-225-2005 3.3V, 12V
- CE-225-2101 5V, 24V
- CE-225-1001 3.3V
- CE-225-1002 5V
- CE-225-1003 12V
- CE-225-1004 15V
- CE-225-1005 24V
- CE-225-1006 28V
- CE-225-1007 48V
- CE-225-1009 39V
Mechanical
- Dimensions 4.75 x 8.0 x 2.0 inches
- Operating Temperature 0°C + 70°C
- MTBF 100,000 Hours min, MIL-HDBK-217F, 25°C, GB
- Cooling Method Free air convection, LFM Forced Air
-
Agency Approvals
General: Protection Class- I, Over voltage catagory- II, Pollution Degree- 2
UL: UL 60950-1, UL 60601-1, CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No.601-1-M90
with updates 1 and 2
TUV: EN 60950-1:2001, EN 60601-1/A2:1995
CE: Low voltage dir
Output
-
Voltage Accuracy
Output 1: ±0.25%
Output 2: ±0.25%(X0XX) ±5%(X1XX)
Output 3: ±2%
Output 4: ±2% - Line Regulation 0.50%
-
Load Regulation
Output 1: 0.5%
Output 2: 0.5%(X0XX) 5%(X1XX)
Output 3: 2%
Output 4: 2% - Minimum Load 10%
-
Protections
Over voltage: Output 1: 110%-150%, shuts down al outputs. Cycle input to restart
Over Current: Output 2,3,4: 110%
Over power: Output 1: 110%, cycle on/off, auto recovery (250 W)