SRW-100

Manufactured by: SRW-100

// AC/DC Power Supplies / Open Frame | Enclosed | U-Chassis

Download PDF Specs »

Features:

  • RoHS Compliant
  • Universal 85~264 VAC input
  • Compact Size
  • One to four tightly regulated outputs
  • EN 60950-1 ITE Certification
  • EN 60601-1 Medical Certification
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • Optional perforated cover

General Specifications

  • Manufacturer Integrated Power Designs
  • Form Factor Open Frame
  • Power 100 Watts
  • Input 85-264 VAC
  • Outputs Sinlge, Dual, Triple, or Quadruple
  • Warranty 2 Year Warranty

Models

Model #

Output

  • SRW-100-4001 3.3V, 5V, 12V, -12V
  • SRW-100-4002 5V, 24V, 12V, -12V
  • SRW-100-4003 5V, 24V, 15V, -15V
  • SRW-100-4004 5V, -5.2V, 12V, -12V
  • SRW-100-4005 5V, -5.2V, 15V, -15V
  • SRW-100-4006 5V, 3.4V, 9V, 24V
  • SRW-100-4007 5V, 15V, 12V, -12V
  • SRW-100-4008 5V, 3.3V, 12V, -5V
  • SRW-100-4009-IT 3.3V, 5V, 12V, -5V
  • SRW-100-4010 5V, 15V, 12V, 9V
  • SRW-100-4011 5V, -15V, 15V, 12V
  • SRW-100-4012 5V, 3.3V, 12V, -12V
  • SRW-100-3001 5V, 12V, -12V
  • SRW-100-3002 5V, 15V, -15V
  • SRW-100-3003 5V, 3.3V, 12V
  • SRW-100-3004 3.3V, 5.8V, -48V
  • SRW-100-2001 12V, -12V
  • SRW-100-2002 15V, -15V
  • SRW-100-2003 12.5V, 16V
  • SRW-100-1001 3.3V
  • SRW-100-1002 5V
  • SRW-100-1003 12V
  • SRW-100-1004 15V
  • SRW-100-1005 24V
  • SRW-100-1006 28V
  • SRW-100-1007 48V
  • SRW-100-1008 40V
  • SRP-100-4001 5V, 24V, 12V, -12V
  • SRP-100-4002 5V, 24V, 15V, -15V
  • SRP-100-4003 5V, -5V, 12V, -12V
  • SRP-100-4004 5V, -5V, 15V, -15V
  • SRP-100-4005 5V, 12V, 8V, -8V
  • SRP-100-3001 5V, 12V, -12V
  • SRP-100-2001 5V, 24V

Mechanical

  • Dimensions 3.3 x 5 x 1.5 inches
  • Operating Temperature 0°C- +70°C
  • MTBF 150,000 Hours min, MIL-HDBK-217F, 25°C, GB
  • Cooling Method Free air convection, LFM Forced Air
  • Agency Approvals General: Protection Class- I, Over voltage catagory- II, Pollution Degree- 2
    UL: UL 60950-1, UL 60601-1, CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No.601-1-M90
    with updates 1 and 2
    TUV: EN 60950-1:2001, EN 60601-1/A2:1995
    CE: Low voltage dir

Output

  • Voltage Accuracy Output 1: ±0.25%
    Output 2: ±0.25%
    (SRP): 5%
    Output 3: ±2%
    Output 4: ±4%
  • Line Regulation 0.50%
  • Load Regulation Output 1: 0.5%
    Output 2: 0.5%
    Output 2 (SRP): 5%
    Output 3: 1%
    Output 4: 1%
  • Minimum Load 10%
  • Protections Over voltage: Output 1: 110%-150%
    Over Current: Output 3&4: 110%
    Over power: Output 1&2: 110%, cycle on/off, auto recovery